elprint@elprint.no
+47 55 92 55 00
  • Våre produkter
    • PCB

      • PCB
      • Spesifikasjoner
      • Rigid
      • Flex og Flex-Rigid
      • Aluminium
      • HDI
      • Rigid-soft
      • Vridningselement

      PCBA

      Testsystemer

      • Testjigg
      • SPRINT

      Mekaniske deler

  • Velocity
  • Om Elprint
    • Hvem er vi
    • Medarbeidere
    • Karriere
    • Åpenhet og bærekraft
    • Kontakt oss
  • Produkter

    PCB

    • PCB
    • Spesifikasjoner
    • Rigid
    • Flex og Flex-Rigid
    • Aluminium
    • HDI
    • Rigid-soft
    • Vridningselement

    PCBA

    • PCBA
    • Spesifikasjoner

    Testsystemer

    • Testjigg
    • SPRINT

    Mekaniske deler

    • Silikonform
    • Somos liquid
    • 3D printing

    Elprint

    • Salg og leveringsbetingelser
    • Sustainability
    • Code of conduct
    • Code of conduct for supplier
    • Persondatapolicy
    • Cookiedeklarasjon

    Kontakt oss

Assembly drawings

Placement Drawings

Specifications and Requirements

Stackup Drawing

Gerber Files

1 2 Neste
+47 55 92 55 00
elprint@elprint.no
Sanddalsringen 5b, 5225 Nesttun
Org.nr. 993 264 318
Varsling
Steg 1 av 2
Legg til filer og antall

PCB

Legg til +

Last opp zip-fil
icon

info om filtyper

PCBA

Legg til +

Last opp zip-fil
icon

info om filtyper

Testsystemer

Legg til +

Last opp zip-fil
icon

info om filtyper

Mekaniske deler

Legg til +

Last opp zip-fil
icon

info om filtyper

Stensiler

Legg til +

Last opp zip-fil
icon

info om filtyper

Hopp over fildeling
Gå videre
Steg 2 av 2
Din informasjon Tilbake til fildeling

Hva skjer når jeg sender inn?

Hvilke filer trenger vi?

PCB

Påkrevd(klikk for mer info)

Specifications

Any text format, usually PDF format

Outline file (Gerber)

A Outline file for each layer (copper layers, solder mask, legend, etc).

All Outline file must have the same origin, orientation, etc.
Images shall not be mirrored, scaled, or rotated.

Outline file must be in “Extended Gerber” format, preferably in 6.6 MM format, with leading zero suppression and absolute coordinates.

We also recommend using Gerber X2 extensions. Drill (template) drawings are not needed.

Gerber Files

A Gerber file for each layer (copper layers, solder mask, legend, etc).

All Gerber files must have the same origin, orientation, etc.
Images shall not be mirrored, scaled, or rotated.

Gerber files must be in “Extended Gerber” format, preferably in 6.6 MM format, with leading zero suppression and absolute coordinates.

We also recommend using Gerber X2 extensions. Drill (template) drawings are not needed.

Drill Files

An NC Drill (or Gerber) file for each drill depth (through holes, each blind hole depth, each buried hole span, etc).

NC Drill files should preferably be in XNC format, alternatively in Excellon format.

NC Drill files should include tool diameters. If not, then a tool list must be supplied for each NC Drill file.

Plated and unplated through holes should preferably be in the same file, but may be in separate files.

NC Drill files should preferably be in 3.3 METRIC format.

Anbefalt(klikk for mer info)

Netlist

A Netlist for each layer (copper layers, solder mask, legend, etc).

All Netlist must have the same origin, orientation, etc.
Images shall not be mirrored, scaled, or rotated.

Netlist must be in “Extended Gerber” format, preferably in 6.6 MM format, with leading zero suppression and absolute coordinates.

We also recommend using Gerber X2 extensions. Drill (template) drawings are not needed.

Pick and Place Files

At the minimum, pick and place files should contain Designator, X and Y coordinates (preferably in mm), and Rotation.

We rcommend that they also include side (top/bottom) and component description.

Most formats are supported.

All Pick and Place components should also be listed in the Bill of Materials.

Hvilke filer trenger vi?

PCBA

Påkrevd(klikk for mer info)

Assembly drawings

Assembly drawings, preferably in PDF format and Gerber

Gerber Files

A Gerber file for each layer (copper layers, solder mask, legend, etc).

All Gerber files must have the same origin, orientation, etc.
Images shall not be mirrored, scaled, or rotated.

Gerber files must be in “Extended Gerber” format, preferably in 6.6 MM format, with leading zero suppression and absolute coordinates.

We also recommend using Gerber X2 extensions. Drill (template) drawings are not needed.

Board profile

A Gerber file with the outer contour (profile) of the board. This may either be a filled polygon or thin line/arc segments.

If the profile is a filled polygon (Gerber region), then the file should not contain any other objects than the polygon. Cutouts, slots and scoring (v-cut), if any, must be in separate Gerber files.

If lines/arcs are used, they must be consecutive (end location of one segment is the start location of the next segment) and form a closed loop without gaps or overlap.

A file with lines/arcs may also contain lines/arcs for cutouts (which must form closed loops), slot centerlines (which must have the same line width as the slot), and/or scoring (v-cut).

Drill Files

An NC Drill (or Gerber) file for each drill depth (through holes, each blind hole depth, each buried hole span, etc).

NC Drill files should preferably be in XNC format, alternatively in Excellon format.

NC Drill files should include tool diameters. If not, then a tool list must be supplied for each NC Drill file.

Plated and unplated through holes should preferably be in the same file, but may be in separate files.

NC Drill files should preferably be in 3.3 METRIC format.

Pick and Place Files

At the minimum, pick and place files should contain Designator, X and Y coordinates (preferably in mm), and Rotation.

We rcommend that they also include side (top/bottom) and component description.

Most formats are supported.

All Pick and Place components should also be listed in the Bill of Materials.

Bill of materials (BOM)

The Bill of Materials should preferably be in a spreadsheet (Excel, OpenOffice, LibreOffice or similar), with one component per row and component data (designator, manufacturer part number, manufacturer, description, value, etc) each in their own columns.

Component data should be as specific as possible.

Anbefalt(klikk for mer info)

Placement Drawings

Placement or assembly drawings, preferably in PDF format

Specifications and Requirements

A text file specifying stackup, surface finish, solder mask color, legend (silkscreen) color, and any other requirements.

If no specification file is provided, then the quotation will be for a PCB with the following specifications:

  • 1.6mm thick rigid board
  • FR-4 standard Tg (IPC-4101/21) material
  • 1 oz (35µm) copper layers
  • Lead-free HASL finish
  • Green soldermask
  • White legend
  • Manufactured in accordance with IPC performance class 2
  • No other options

Stackup Drawing

If you require a stackup with specified distance between inner layers, or that has special material requirements, or the PCB is flexible, flex-rigid or metal-based, then a detailed stackup drawing must be supplied.

IPC-D-365 test pad file: Include this file if your system can generate a test pad file in IPC-D-356 format.

Gerber Job file: Include this file if your system can generate a Gerber Job file in .gbrjob format.

Hvilke filer trenger vi?

Testsystemer

Påkrevd(klikk for mer info)

3D model of board under test

3D model of board under test

Testpoint locations

Testpoint locations, preferably in Pick and Place format

Gerber Files

A Gerber file for each layer (copper layers, solder mask, legend, etc).

All Gerber files must have the same origin, orientation, etc.
Images shall not be mirrored, scaled, or rotated.

Gerber files must be in “Extended Gerber” format, preferably in 6.6 MM format, with leading zero suppression and absolute coordinates.

We also recommend using Gerber X2 extensions. Drill (template) drawings are not needed.

Board profile

A Gerber file with the outer contour (profile) of the board. This may either be a filled polygon or thin line/arc segments.

If the profile is a filled polygon (Gerber region), then the file should not contain any other objects than the polygon. Cutouts, slots and scoring (v-cut), if any, must be in separate Gerber files.

If lines/arcs are used, they must be consecutive (end location of one segment is the start location of the next segment) and form a closed loop without gaps or overlap.

A file with lines/arcs may also contain lines/arcs for cutouts (which must form closed loops), slot centerlines (which must have the same line width as the slot), and/or scoring (v-cut).

Drill Files

An NC Drill (or Gerber) file for each drill depth (through holes, each blind hole depth, each buried hole span, etc).

NC Drill files should preferably be in XNC format, alternatively in Excellon format.

NC Drill files should include tool diameters. If not, then a tool list must be supplied for each NC Drill file.

Plated and unplated through holes should preferably be in the same file, but may be in separate files.

NC Drill files should preferably be in 3.3 METRIC format.

Hvilke filer trenger vi?

Mekaniske deler

Påkrevd(klikk for mer info)

3D model (stl and/or stp files)

3D model (stl and/or stp files)

Specifications

Any text format, usually PDF format

Hvilke filer trenger vi?

Stensiler

Påkrevd(klikk for mer info)

Gerber Files

A Gerber file for each layer (copper layers, solder mask, legend, etc).

All Gerber files must have the same origin, orientation, etc.
Images shall not be mirrored, scaled, or rotated.

Gerber files must be in “Extended Gerber” format, preferably in 6.6 MM format, with leading zero suppression and absolute coordinates.

We also recommend using Gerber X2 extensions. Drill (template) drawings are not needed.

Board profile

A Gerber file with the outer contour (profile) of the board. This may either be a filled polygon or thin line/arc segments.

If the profile is a filled polygon (Gerber region), then the file should not contain any other objects than the polygon. Cutouts, slots and scoring (v-cut), if any, must be in separate Gerber files.

If lines/arcs are used, they must be consecutive (end location of one segment is the start location of the next segment) and form a closed loop without gaps or overlap.

A file with lines/arcs may also contain lines/arcs for cutouts (which must form closed loops), slot centerlines (which must have the same line width as the slot), and/or scoring (v-cut).

Hva skjer når jeg sender inn?

En av våre medarbeidere mottar filene dine og gjennomgår forespørselen for å gi deg et nøyaktig prisestimat. Alle filer behandles konfidensielt og deles aldri med uvedkommende. Vi lagrer heller ingen filer utover det som er nødvendig for å gi deg svar.

Produkter
PCB
PCBA
Testsystemer
Mekaniske deler
Stensiler
Elprint
Hvem er vi
Våre kontorer
Medarbeidere
Kontakt
Åpenhet og bærekraft
Salg og leveringsbetingelser
Sustainability
Code of conduct
Code of conduct for supplier
Persondatapolicy
Cookiedeklarasjon
Teknologi
Orcad Macaos output
Guides til Macaos Enterprise
Bestilling med Macaos Enterprise
Popup Trigger